Lemo1, 5 pin female
010744_001
1
2
3
5
4
Pin Name Function
1 PWR_IN Power-In, 24 V
2 NC Do not connect
3 GND Ground
4 GND Ground
5 PWR_IN Power-In, 24 V
6.5 Environmental Specications
6.5.1 RTC360/RTC360 LT
Temperature range:
Type Operating temperature
[°C]
Storage temperature
[°C]
RTC360/RTC360 LT −5 to +40 −40 to +70
Protection against water, dust and sand:
Type Protection
RTC360/RTC360 LT IP54 (IEC 60529), upright ±15°/
upside down ±15°
Dust protected
Protection against splashing water from any dir-
ection
IP51 (IEC60529), in any other position
Dust protected
Protection against dripping water
Humidity:
Type Protection
RTC360/RTC360 LT Max 95% non-condensing
Lighting:
Type Conditions
RTC360/RTC360 LT Fully operational from bright sunlight to complete
darkness.
Power supply port
Environmental spe-
cications RTC360/
RTC360 LT
48 Technical Data