12.5 Required drawbar load
Specication Value
Required drawbar load At least 4% of the weighed machine weight
or 500 kg
12.6 Performance data
n Recommended operating speed 12 km/h
n Working on slopes max. +/- 20°
n Operating temperature range 0°C to 50°C
Permitted tractor power
Karat 10 300 350 400
Tractor power
minimum...maximum
[HP] 105...180 123...210 140...240
[kW] 77...132 90...154 103...176
12.7 Connection data
12.7.1 Electrical connections
Voltage sources
Consumer Voltage
[Volt]
Direct connection
to the tractor battery
Power socket
Lighting equipment 12 - According to DIN ISO 1724
Lighting equipment
(Canada, USA)
12 - According to ISO 1185
Voltage tolerance range: 10 V to 15 V
12.7.2 Hydraulic connections
Design according to ISO 4413
Ambient and operating conditions
Tractor power requirements
Technical data
en-GB | Item no. 17516276 | BA 01/2023-09 80