Faults
Pro Control Faults
Fault Indicator –
actuators, true of auto
or assist
Status Cause Resolution
Right, and/or left hand,
LEDs flashing fast
Port, or starboard,
actuator is not
responding
One or both, actuators
not extending per drive
command
Keypad not
communicating
with port or
starboard actuator
Faulty actuator
Recommission Pro
Control system
Navico Group™ service
Medium flash for all left,
or right hand, LEDs
Actuator still moves
but will not move to
a position command,
only moved by jogs,
while all LEDs are
flashing
Faulty actuator Navico Group™ service
Periodic flash, shows %
position but every ten
seconds all left side, or
right side, LEDs flash
The port actuator had
a temporary fault that
reset
n/a Actuator faults will
self clear
If a fault continues to
display, then the fault
condition is still present
Both FAV LEDs
flash twice
n/a No FAV 1 or FAV 2
stored
Save FAV trim tab
position
FAV 1 and FAV 2 will not
light up, or turns o if
lit without touching any
other buttons and will
not turn back on
Will also show fault blink
on LEDs
A critical, or a
non-critical, fault in an
actuator has occurred
Faulty actuator Navico Group™ service
AUTO, or HOLD, button
led will double flash
n/a IMU not
communicating
Boat not on plane
Navico Group™ service
Secure all NMEA®
cabling connections
Recalibration Pro
Control Auto system
Both Auto & Hold, or
both FAVs, double flash
when trying to enter
locating mode
SOG higher than
6 mph
SOG higher than
6 mph
Slow boat speed to less
than 6 mph
Things to Consider When Troubleshooting
1. Make sure you check all connections and wiring for corrosion, as this can cause
unforeseen problems
2. Make sure you have a fully charged battery and terminals are free of corrosion
For More information on additional troubleshooting, or any of the Lenco Marine products
please visit our website: lencomarine.com