EasyManua.ls Logo

Lenovo ThinkSystem SR550 - Page 92

Lenovo ThinkSystem SR550
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Read the
installation
Guidelines” on
page 46
Power off
the server
for this task”
on page 90
ATTENTION:
Static Sensitive Device
Ground package before opening”
on page 48
Notes:
For a list of supported drives, see
http://www.lenovo.com/us/en/serverproven/.
The drive bays are numbered to indicate the installation order (starting from number “0”). Follow the
installation order when you install a drive. See “Front view” on page 15.
You can mix drives of different types and different capacities in one system, but not in one RAID array.
The following order is recommended when installing the drives:
Drive type priority: SATA SSD, SATA HDD
Drive capacity priority: the lowest capacity first
The drives in a single RAID array must be the same type, same size, and same capacity.
Before installing a simple-swap drive:
1. If there is a drive filler installed, remove it and keep it in a safe place.
Figure 60. Drive filler removal
2. Touch the static-protective package that contains the new drive to any unpainted surface on the outside
of the server. Then, take the new drive out of the package.
To install a simple-swap drive, complete the following steps: