EasyManua.ls Logo

Lenovo ThinkSystem SR650 Series - Page 106

Lenovo ThinkSystem SR650 Series
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Server model: twelve 2.5-inch SAS/SATA drives, twelve 2.5-inch SAS/SATA/NVMe drives, one 24i RAID
adapter, two NVMe switch adapters
Figure 60. Cable routing for server models with twelve 2.5-inch SAS/SATA drives, twelve 2.5-inch SAS/SATA/NVMe
drives, one 24i RAID adapter, and two NVMe switch adapters
Cable From To
1 Power cable for front backplane 1 Power connector on front backplane
1
Backplane power connector 1 on the
system board
2 SAS signal cable for front
backplane 1
SAS 0 and SAS 1 connectors on front
backplane 1
C0 and C1 connectors on the 24i
RAID adapter installed in PCIe slot 6
3 NVMe signal cable for front
backplane 1
NVMe 0, NVMe 1, NVMe 2, and
NVMe 3 connectors on front
backplane 1
NVMe 0–1 and NVMe 2–3 connectors
on the system board
4 NVMe signal cable for front
backplane 2
NVMe 0, NVMe 1, NVMe 2, and
NVMe 3 connectors on front
backplane 2
C0, C1, C2, and C3 connectors on
the NVMe switch adapter installed in
PCIe slot 5
5 SAS signal cable for front
backplane 2
SAS 0 and SAS 1 connectors on front
backplane 2
C2 and C3 connectors on the 24i
RAID adapter installed in PCIe slot 6
6 Power cable for front backplane 2 Power connector on front backplane
2
Backplane power connector 2 on the
system board
7 SAS signal cable for front
backplane 3
SAS 0 and SAS 1 connectors on front
backplane 3
C4 and C5 connectors on the 24i
RAID adapter installed in PCIe slot 6
102 ThinkSystem SR650 Setup Guide

Table of Contents