Table 30.   PCIe switch adapters and the corresponding PCIe slots
Type of PCIe switch adapter
PCIe slot selection
810-4P NVMe switch adapter (with the 2U bracket 
installed)
Slot 4 on the system board
810-4P NVMe switch adapter RAID adapter slot on the system board
1610-4P NVMe switch adapter
Slot 1 on riser card 1
1610-4P NVMe switch adapter
Slot 5 on riser card 2
1610-4P NVMe switch adapter
Slot 6 on riser card 2
Watch the procedure. A video of the installation process is available: 
•  Youtube: 
https://www.youtube.com/playlist?list=PLYV5R7hVcs-A25P7vBoGa_wn7D7XTgDS_
•  Youku: http://list.youku.com/albumlist/show/id_50483444
Step 1.  Install the three 2.5-inch NVMe 8-Bay backplanes. See Install the 2.5-inch-drive backplane. Then, 
apply drive bay sequence labels above the drive bays on your server. 
Step 2.  Install the bracket on one 810-4P NVMe switch adapter. To install the bracket, align the screw 
holes in the bracket with the corresponding holes in the switch adapter, and then install the screws 
to secure the bracket to the switch adapter.
Step 3.  Install the 810-4P NVMe switch adapter in the RAID adapter slot on the system board. See 
Install 
the RAID adapter
.
Step 4.  Install the 810-4P NVMe switch adapter with 2U bracket in PCIe slot 4 on the system board. See 
Install a PCIe adapter on the system board.
Step 5.  Install the riser card 1 on riser 1 bracket. See 
Install a riser card.
Step 6.  Install the 1610-4P NVMe switch adapter in PCIe slot 1 on riser card 1. See 
Install a PCIe adapter on 
the riser assembly
.
Step 7.  Install the riser 1 assembly to the chassis. See 
Install a riser card.
Step 8.  Install the riser card 2 on riser 2 bracket. See 
Install a riser card.
Step 9.  Install one 1610-4P NVMe switch adapter in PCIe slot 5 on riser card 2. Then, install the other 
1610-4P NVMe switch adapter in PCIe slot 6 on riser card 2. See 
Install a PCIe adapter on the riser 
assembly
.
Step 10.  Install the riser 2 assembly to the chassis. See 
Install a riser card.
Step 11.  Install any required hardware or server options, and then cable the server. For information about 
how to connect cables for server models with twenty NVMe drives, see “Server model: twenty 2.5- 
inch NVMe drives, two NVMe 810-4P switch adapters, three NVMe 1610-4P switch adapters” in 
the topic 
Server models with twenty 2.5-inch drives.
Install the U.2 24-Bay upgrade kit
Use this information to install the U.2 24-Bay upgrade kit.
“Read the  
installation  
Guidelines” on 
page 126
“Power off 
the server for 
this task” on 
page 194
“ATTENTION:  
Static Sensitive Device  
Ground package before opening” 
on page 127
The following information is a summary of the PCIe switch adapters and the corresponding PCIe slots. For 
information about PCIe slot location, refer to “Rear view” on page 26. 
180
ThinkSystem SR650 Setup Guide