Server model: sixteen 2.5-inch SAS/SATA drives, the rear hot-swap drive assembly, one 24i RAID
adapter
Note: The cable routing illustration is based on the scenario that the rear hot-swap drive assembly is
installed. Depending on the model, the rear hot-swap drive assembly and the cable
5 might not be available
on your server.
Figure 32. Cable routing for server models with sixteen 2.5-inch SAS/SATA drives, the rear hot-swap drive assembly, and
one 24i RAID adapter
Cable
From To
1 Power cable for front backplane 1 Power connector on front backplane
1
Backplane power connector 1 on the
system board
2 SAS signal cable for front
backplane 1
SAS 0 and SAS 1 connectors on front
backplane 1
C0 and C1 connectors on the 24i
RAID adapter installed in PCIe slot 5
3 SAS signal cable for front
backplane 2
SAS 0 and SAS 1 connectors on front
backplane 2
C2 and C3 connectors on the 24i
RAID adapter installed in PCIe slot 5
56 ThinkSystem SR650 Setup Guide