Loading...
Server model: eight 2.5-inch SAS/SATA drives, eight 2.5-inch SAS/SATA/NVMe drives, one 16i RAID
adapter, one NVMe switch adapter
Note: The cable routing illustration is based on the scenario that the NVMe switch adapter is installed in
PCIe slot 1. If the NVMe switch adapter is installed in PCIe slot 5 or PCIe slot 6, route the NVMe signal cable
for front backplane 2 along the left side of the chassis.
Figure 38. Cable routing for server models with eight 2.5-inch SAS/SATA drives, eight 2.5-inch SAS/SATA/NVMe drives,
one 16i RAID adapter, and one NVMe switch adapter
Cable
From To
1 Power cable for front backplane 1 Power connector on front backplane
1
Backplane power connector 1 on the
system board
2 SAS signal cable for front
backplane 1
SAS 0 and SAS 1 connectors on front
backplane 1
C0 and C1 connectors on the 16i
RAID adapter installed on the RAID
adapter slot
3 NVMe signal cable for front
backplane 1
NVMe 0, NVMe 1, NVMe 2, and
NVMe 3 connectors on backplane 1
NVMe 0–1 and NVMe 2–3 connectors
on the system board
4 SAS signal cable for front
backplane 2
SAS 0 and SAS 1 connectors on front
backplane 2
C2 and C3 connectors on the 16i
RAID adapter installed on the RAID
adapter slot
64 ThinkSystem SR650 Setup Guide