EasyManua.ls Logo

Lenovo ThinkSystem SR650 Series - Page 83

Lenovo ThinkSystem SR650 Series
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Server model: twenty-four 2.5-inch SAS/SATA drives, the rear hot-swap drive assembly, two 8i RAID
adapters, one 16i RAID adapter
Figure 47. Cable routing for server models with twenty-four 2.5-inch SAS/SATA drives, the rear hot-swap drive assembly,
two 8i RAID adapters, and one 16i RAID adapter
Cable
From To
1 Power cable for front backplane 1 Power connector on front backplane
1
Backplane power connector 1 on the
system board
2 SAS signal cable for front
backplane 1
SAS 0 and SAS 1 connectors on front
backplane 1
C0 and C1 connectors on the 8i RAID
adapter installed on the RAID adapter
slot
3 SAS signal cable for front
backplane 2
SAS 0 and SAS 1 connectors on front
backplane 2
C0 and C1 connectors on the 8i RAID
adapter installed in PCIe slot 4
4 Power cable for front backplane 2 Power connector on front backplane
2
Backplane power connector 2 on the
system board
5 Power cable for front backplane 3 Power connector on front backplane
3
Backplane power connector 3 on the
system board
6 SAS signal cable for front
backplane 3
SAS 0 and SAS 1 connectors on front
backplane 3
C0 and C1 connectors on the 16i
RAID adapter installed in PCIe slot 5
7 SAS signal cable for the rear hot-
swap drive assembly
Signal connector on the rear hot-
swap drive assembly
C2 connector on the 16i RAID
adapter installed in PCIe slot 5
Chapter 2. Server components 79

Table of Contents

Related product manuals