EasyManua.ls Logo

Lenovo ThinkSystem SR650 Series - Page 90

Lenovo ThinkSystem SR650 Series
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Server model: twenty 2.5-inch SAS/SATA drives, four 2.5-inch SAS/SATA/NVMe drives, the rear hot-
swap drive assembly, four 8i RAID adapters
Note: The cable routing illustration is based on the scenario that the rear hot-swap drive assembly is
installed. Depending on the model, the rear hot-swap drive assembly and the 8i RAID adapter in PCIe slot 6
might not be available on your server.
Figure 52. Cable routing for server models with twenty 2.5-inch SAS/SATA drives, four 2.5-inch SAS/SATA/NVMe drives,
the rear hot-swap drive assembly, and four 8i RAID adapters
Cable
From To
1 Power cable for front backplane 1 Power connector on front backplane
1
Backplane power connector 1 on the
system board
2 SAS signal cable for front
backplane 1
SAS 0 and SAS 1 connectors on front
backplane 1
C0 and C1 connectors on the 8i RAID
adapter installed on the RAID adapter
slot
3 NVMe signal cable for front
backplane 1
NVMe 0, NVMe 1, NVMe 2, and
NVMe 3 connectors on front
backplane 1
NVMe 0–1 and NVMe 2–3 connectors
on the system board
4 SAS signal cable for front
backplane 2
SAS 0 and SAS 1 connectors on front
backplane 2
C0 and C1 connectors on the 8i RAID
adapter installed in PCIe slot 4
5 Power cable for front backplane 2 Power connector on front backplane
2
Backplane power connector 2 on the
system board
6 Power cable for front backplane 3 Power connector on front backplane
3
Backplane power connector 3 on the
system board
86 ThinkSystem SR650 Setup Guide