• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
A video for this task is available at:
• Youtube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-Bz2XIeLEfGcrLGm9TSY_yt
• Youku: http://list.youku.com/albumlist/show/id_52339612.html
Procedure
Step 1. Check the server.
a. Ensure that no tools or loose screws are left inside your server.
b. Ensure that all components have been reassembled correctly.
c. Ensure that all cables inside the server have been properly routed and they will not interfere
with installing the air baffle.
Step 2. Note the orientation of the air baffle.
Step 3. Align the tabs on both sides of the air baffle with the corresponding slots on both sides of the
chassis. Then, lower the air baffle into the chassis and press the air baffle down until it is securely
seated.
Note: The illustration shows the installation of the standard air baffle. The procedure is the same
for GPU air baffle.
Figure 109. Installation of the standard air baffle
Install the top cover
Use this information to install the top cover.
About this task
Chapter 4. Server hardware setup 225