Step 1. If an adapter filler is installed in the slot, remove it.
Step 2. Align the PCIe adapter with the alignment slot and the connector on the 4U PCIe riser assembly;
then, insert the PCIe adapter into the connector. Make sure the PCIe adapter is fully seated into the
connector.
Note: If your PCIe adapter comes with a power cable, connect it to the 4U PCIe riser card.
Step 3. Close the retention latch to firmly secure the PCIe adapter into the 4U PCIe riser assembly.
Figure 156. PCIe adapter installation
Step 4. Align the 4U PCIe riser air baffle with the guide pin; then, make sure the guide pin and the two clips
on the 4U PCIe riser assembly are respectively inserted into the alignment hole and slots on the 4U
PCIe riser air baffle.
Step 5. Slightly press the 4U PCIe riser air baffle until it clicks.
Chapter 3. Hardware replacement procedures 165