5 Appendix: Action types for the positioning sequence control
5.3 Branching
48
Lenze · 8400 "Position Sequencer" technology application · Software manual · DMS 1.0 EN · 07/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.3 Branching
For conditional and unconditional branching (jumps), 16 actions of "Branching" Type are available.
Parameter Possible settings Info
Input f. jump
(C01415/1...16)
0 Unconditional branch "Unconditional branch": There is
always a branch to the jump
destination set.
1 Sequencer input 1
(Bit 0 of wDigitalInputs)
"Conditional branch": There only is a
branch to the jump destination set if
the sequencer input selected has the
polarity set. Otherwise the next step
in the sequence table is processed.
2 Sequencer input 2
(Bit 1 of wDigitalInputs)
... ...
16 Sequencer input 16
(Bit 15 of wDigitalInputs)
Polarity of input
(C01416/1...16)
Condition is bit state "0" State which the sequencer input
selected must have for a conditional
branch.
Condition is bit state "1"
Jump destination
(C01417/1...16)
0 Sequence step For a conditional branch, there only is
a branch to the jump destination set
here if the sequencer input selected
has the polarity set. Otherwise the
next step in the sequence table is
processed.
1...100 Step 1 ... 100