Lenze · 8400 "Position Sequencer" technology application · Software manual · DMS 1.0 EN · 07/2014 · TD05 53
5 Appendix: Action types for the positioning sequence control
5.8 Wait
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.8 Wait
For integrating waiting times into the program flow, 8 actions of the "Wait" type are provided.
The sequence step is only processed
after a waiting time has elapsed,
OR
when a selectable sequencer input has a specific level.
Parameter Possible settings Info
Waiting time
(C01438/1...8)
0.000 s 2127480.000 Waiting time for "Wait" function
The setting "0" deactivates the
waiting time.
Initialisation: 1.000 s
Input for "Next"
(C01439/1...8)
0 Input deactivated "Wait": Sequence step is only
processed after the waiting time set
has elapsed.
1 Sequencer input 1
(Bit 0 of wDigitalInputs)
"Wait for level": Sequence step is only
processed when the sequencer input
selected has the polarity set.
Note!
However, if a waiting time > 0 s is set,
the sequence step is processed at the
latest after the waiting time set has
elapsed.
2 Sequencer input 2
(Bit 1 of wDigitalInputs)
... ...
16 Sequencer input 16
(Bit 15 of wDigitalInputs)
Polarity of input
(C01440/1...16)
Condition is bit state "0" State which the sequencer input
selected must have so that the
sequence step is processed.
Condition is bit state "1"