Lenze · 8400 "Position Sequencer" technology application · Software manual · DMS 1.0 EN · 07/2014 · TD05 51
5 Appendix: Action types for the positioning sequence control
5.6 Counter setting
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.6 Counter setting
For setting one of the 5 available counters to a certain starting value, 5 actions of "Counter setting"
type are available.
The 5 actions of "counter setting" type are not
permanently assigned to the 5 counters.
You can, e.g., set a counter to a value using an action of "counter setting" type and at a later
program time set the same counter to a different value using another action of "counter
setting" type.
Tip!
Since for the "Count" action also negative step values can be set, it is also possible to count
down from a starting value that is set.
Parameter Possible settings Info
Counter No.
(C01441/1...5)
0 Counter setting deactivated Selection of the counter
1Counter 1
... ...
5Counter 5
Starting value
(C01442/1...5)
-2147483647 2147483647 Value to which the counter selected
is to be set.
Initialisation: 0