Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06 105
14 Parameter reference
14.2 Parameters of the communication module for slot MXI1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13484
C13489
C13531
Parameter | Name:
C13484 | Active RPDO channel
Data type: UNSIGNED_8
Index: 11091 = 0x2B53
This code is for device-internal use only and must not be written to by the user!
Selection of the active RPDO channel
Selection list Info
0No RPDO
1 RPDO-1 (I-1600)
... ...
10 RPDO-10 (I-1609)
Subcodes Lenze setting Info
C13484/1 1: RPDO-1 (I-1600) Active RPDO channel
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13489 | No. of RPDO mapping entries
Data type: UNSIGNED_8
Index: 11086 = 0x2B4E
This code is for device-internal use only and must not be written to by the user!
Subcodes 1 ... 10 specify the number of valid mapping entries of the RPDO channels 1 ... 10 (valid subcodes in
C13231
... C13240).
Setting range (min. value | unit | max. value)
032
Subcodes Lenze setting Info
C13489/1 0 No. of mapping entries for RPDO-1
... ... ...
C13489/10 0 No. of mapping entries for RPDO-10
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13531 | Mapping entries TPDO-1
Data type: UNSIGNED_64
Index: 11044 = 0x2B24
This code is for device-internal use only and must not be written to by the user!
Subcodes 1 ... 32 specify the mapping for the TPDO channel 1.
• Servo Drives 9400 exclusively support mapping objects with a data length of 8 bits (1 byte) or a multiple of this
value. Incompatible objects must be mapped to variables with a compatible data length.
• The master must have the same mapping entries as the slave.
Structure of the mapping codes
( 66)
Value is bit-coded: Info
Bit 0 Bit 0
... ...
Bit 63 Bit 63
Subcodes Lenze setting Info
C13531/1 0 1. mapping entry TPDO-1 (I-1A00.01)
... ... ...
C13531/32 0 32. mapping entry TPDO-1 (I-1A00.20)
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT