14 Parameter reference
14.2 Parameters of the communication module for slot MXI1
112
Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13853
C13858
C13859
C13860
Parameter | Name:
C13853 | All words from standard device
Data type: UNSIGNED_16
Index: 10722 = 0x29E2
Display of the process data words (subcodes 1 ... 32) which are transferred from the standard device to the
communication module.
Display range (min. value | unit | max. value)
0 65535
Subcodes Info
C13853/1
...
C13853/32
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13858 | Safety-over-EtherCAT (FSoE) active
Data type: UNSIGNED_8
Index: 10717 = 0x29DD
Available from SW version 04.00.
Display of the activity of Safety over EtherCAT
( 81)
Selection list (read only) Info
0 Not active
1 Enable
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13859 | Length of the configured input data
Data type: UNSIGNED_8
Index: 10716 = 0x29DC
Available from SW version 04.00.
Display of the length of the configured input data in bytes
Display range (min. value | unit | max. value)
0 255
Subcodes Info
C13859/1 TxPDO length
C13859/2 Safety-TxPDO length
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13860 | Length of the configured output data
Data type: UNSIGNED_8
Index: 10715 = 0x29DB
Available from SW version 04.00.
Display of the length of the configured output data in bytes
Display range (min. value | unit | max. value)
0 255
Subcodes Info
C13859/1 RxPDO length
C13859/2 Safety-RxPDO length
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT