14 Parameter reference
14.3 Parameters of the communication module for slot MXI2
130
Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14853
C14858
C14859
C14860
Parameter | Name:
C14853 | All words from standard device
Data type: UNSIGNED_16
Index: 9722 = 0x25FA
Display of the process data words (subcodes 1 ... 32) which are transferred from the standard device to the
communication module.
Display range (min. value | unit | max. value)
0 65535
Subcodes Info
C14853/1
...
C14853/32
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14858 | Safety-over-EtherCAT (FSoE) active
Data type: UNSIGNED_8
Index: 9717 = 0x25F5
Available from SW version 04.00.
Display of the activity of Safety over EtherCAT
( 81)
Selection list (read only) Info
0 Not active
1 Enable
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14859 | Length of the configured input data
Data type: UNSIGNED_8
Index: 9716 = 0x25F4
Available from SW version 04.00.
Display of the length of the configured input data in bytes
Display range (min. value | unit | max. value)
0 255
Subcodes Info
C14859/1 TxPDO length
C14859/2 Safety-TxPDO length
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14860 | Length of the configured output data
Data type: UNSIGNED_8
Index: 9715 = 0x25F3
Available from SW version 04.00.
Display of the length of the configured output data in bytes
Display range (min. value | unit | max. value)
0 255
Subcodes Info
C13859/1 RxPDO length
C13859/2 Safety-RxPDO length
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT