Appendix
Code table
14−22
L
EDB82MV752 EN 5.2
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0135
*
Controller control
word (parameter
channel)
Bit Assignment
Control via parameter channel. The most
important control commands are
grouped as bit commands.
C0135 cannot be changed using the
keypad
1|0 JOG1, JOG2, JOG3 or C0046 (NSET1−JOG1/3,
NSET1−JOG2/3)
00
01
10
11
C0046 active
JOG1 (C0037) active
JOG2 (C0038) active
JOG3 (C0039) active
2
0
1
Current direction of rotation (DCTRL1−CW/CCW)
not inverted
inverted
3
0
1
Quick stop (DCTRL1−QSP)
not active
active
4
0
1
Stop ramp function generator
(NSET1−RFG1−STOP)
not active
active
5
0
1
Ramp function generator input = 0
(NSET1−RFG1−0)
not active
active (deceleration to C0013)
RFG1 = Ramp function generator main
setpoint
6
0
1
UP function motor potentiometer (MPOT1−UP)
not active
active
7
0
1
DOWN function motor potentiometer
(MPOT1−DOWN)
not active
active
8 Reserved
9
0
1
Controller inhibit (DCTRL1−CINH)
Controller enabled
Controller inhibited
10 TRIP set (DCTRL1−TRIP−SET) Sets "external error" in the controller
(
EEr, LECOM No. 91)
11
0 1
TRIP reset (DCTRL1−TRIP−RESET)
Edge causes TRIP reset
13|12 Parameter set changeover (DCTRL1−PAR2/4,
DCTRL1−PAR3/4)
00
01
10
11
PAR1
PAR2
PAR3
PAR4
14
0
1
DC injection brake (MTCRL1−DCB)
not active
active
15 Reserved
C0138* Process controller
setpoint 1
(PCTRL1−SET1)
0.00 −650.00 {0.02 Hz} 650.00 The value set will be lost when
switching the mains!
Selection if C0412/4 = FIXED−FREE
Display if C0412/4 FIXED−FREE
7−53
C0140* Additive frequency
setpoint
(NSET1−NADD)
0.00 −650.00 {0.02 Hz} 650.00 Selection via function of the
keypad or the parameter channel
Is added to main setpoint
Value is stored when switching the
mains or removing the keypad
7−45