from Firmware V06.00 - DMS 1.1 EN - 11/2011 L 17
8400 StateLine C | Operating instructions
Before commissioning
General notes on parameters
 
Menu structure
In the keypad, the parameters are classified into various menus and submenus.
 The USER menu includes a selection of frequently used parameters.
 ( 21)
 The Code list contains all parameters.
 The Go to param function enables you to reach the corresponding parameter directly.
 The Logbook logs all errors and their chronological history.
 The Diagnostics menu contains diagnostic/display parameters for displaying device-
internal process factors, current actual values and status messages.
General operation
[5-1] Example: Change parameter with the keypad
1. Use the / navigation keys to select the 
desired menu.
–Use the / navigation keys to reach a 
higher/lower menu level.
–Use the  function key to return to the 
main menu.
2. Use the / navigation keys to select the 
parameter to be set within a submenu.
3. In order to select another subcode in case of 
a parameter with subcodes:
– Press the navigation key  to change tot 
he editing mode for the subcode.
– Use the navigation keys to set the 
desired subcode.
4. Use the  function key to switch over to 
the editing mode.
5. Use the navigation keys to set the desired 
value.
6. Use the  function key to accept the 
change and to leave the editing mode.
– Use the  function key to leave the 
editing mode without accepting the 
change.
Load Lenze setting
C00002/001
Off / Finished
EDIT
Par1 8400 StateLine C
SAVE
Code list
Go To Param
USER - Menu
Fixed setpoint 1
C00039/001
40.00 %
EDIT
Fixed setpoint 2
60.00 %
EDIT
C00039/002
Fixed setpoint 2
C00039/002
ESC
60.00 %
OK
1.
2.
3.
5.
4.
6.