EasyManua.ls Logo

Lenze ECSEM Series - Page 288

Lenze ECSEM Series
375 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
Code table
12
288
EDBCSXM064 EN 11.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C0135 Control word 0
System control word DCTRL
0 {1} 65535 Controller evaluates information
as 16 bits (binary−coded)
Bit 0 Not assigned
Bit 1 Not assigned
Bit 2 Not assigned
Bit 3 Quick stop (QSP)
Bit 4 Not assigned
Bit 5 Not assigned
Bit 6 Not assigned
Bit 7 Not assigned
Bit 8 Operation inhibit (DISABLE)
Bit 9 Controller inhibit (CINH)
Bit 10 TRIP−SET
Bit 11 TRIP−RESET
Bit 12 Not assigned
Bit 13 Not assigned
Bit 14 Not assigned
Bit 15 Not assigned
C0136 Control words
Hexadecimal value is bit−coded.
Read only
1 CTRLWORD
0 {hex} FFFF
Control word C0135
2 CTRLWORD CAN control word
3 CTRLWORD AIF control word
C0141 FCODE(setval) 0.0
Main setpoint (FCODE_C141_a)
−199.99 {0.01 %} 199.99
C0142 Start options 1
Starting condition for start after
l mains connection
l message (t > 0.5 s)
l TRIP
0 Protection against unexpected start−up
1 Automatic start

Table of Contents

Other manuals for Lenze ECSEM Series

Related product manuals