Technical data
L
57
EDBEPM-H520 DE/EN/FR 4.0
2.2 Electrical data
Field Values
Display
Type LCD, 256 colours, 10.4
D
i
s
p
l
a
y
Display format graphical
Touch screen Matrix 40 x 30 (16 x 16 pixels each)
Resolution 640 x 480 pixels
Visible size 211.2 x 158.0 mm
Lines Characters
100 %
200 %
400 %
7x20
15 x 40
30 x 80
Character size
100 %
200 %
400 %
2.7x5.4mm,text:8x16pixels
5.4 x 10.7 mm, text: 16 x 32 pixel
10.7 x 21.4 mm, text: 32 x 64 pixels
Fonts programmable
Contrast setting via touch screen
Background light
Service life at 25 °C
CCFL tube
30000 h
Electrical connection
DC voltage supply +18 ... 32 VDC
E
l
e
c
t
r
i
c
a
l
c
o
n
n
e
c
t
i
o
n
Power consumption 15 W at 24 VDC
Fusing Miniature fuse 5 x 20 mm, 1.25 A / F
Network:
System bus (CAN)
Protocol Lenze System bus (CAN)
S
y
s
t
e
m
b
u
s
(
C
A
N
)
Communication medium DIN ISO 11898
Network topology Line (terminated at both ends with 120 )
System bus devices Master or slave
Max. number of devices 63
Baud rate [kBit/s] 20 50 125 250 500 1000
Max. bus length [m] 2500 1000 500 250 80 25
Memory
User project 2MB
M
e
m
o
r
y
Data memory
(energy-dependent, can only be
used with an internal buffer
battery)
256 kB
Flash module (optional)
Memory extension 4MB
Backup 8MB
Interfaces
Serial
I
n
t
e
r
f
a
c
e
s
MSP (DB25 socket) RS232
Parallel
LPT (DB25 socket) Centronics
Battery Saving of internal data and
real-time clock with data)
Lithium battery 3 V, 19 mm
Show/Hide Bookmarks