Installation
L
65
EDBEPM-H520 DE/EN/FR 4.0
3.2 Electrical installation
3.2.1 Assignment of the connection terminals
$
$$
$
Stop!
!
Damage of units connected. Connect the PE conductor as shown in the picture!
!
Wire the keypad when no voltage is applied!
1
2
3
4
5
+24 VDC
N.C.
0 VDC
CAN+
N.C.
Shield
CAN-
V-
1
2
3
4
INPUT VOLTAGE:
18 - 32 VDC 15 W
fuse 1.25 A
MSP
LPT
CAN-GND
CAN-LO
CAN-HI
back-up expansion
PE
N
L1
0
~
–
+18...32VDC
h520_004
Fig. 3-1 Assignment of the connection terminals
DC voltage supply
Terminal Name Explanat ion
1 +24 VDC Voltage supply (+18 V ... 32 VDC)
2 0VDC GND voltage supply , reference potential
3 N.C. Not connected
4 PE potential
System bus ( CAN)
Terminal Name Explanat ion
1 V- GND Reference potential
2 CAN- LO System bus LOW (data line)
3 Shield Connect the shield of the system bus cable
4 CAN+ HI System bus HIGH (data line)
5 N.C. Not connected