Operation 3
3.5 Details of the Copied Data
3.5.1 8400 Series Memory Module
8400 Inverter Type
EPM Attributes SL HL TL TL Vx protec
Master memory module MM100 / E84AYM10S E84AYM30S
Target memory module MM100 / E84AYM10S E84AYM30S
Master drive data from:
can be copied and used in...
SL HL TL TL Vx protec
target drive = SL Yes
target drive = HL Yes Yes
target drive = TL Yes Yes Yes
target drive = TL Vx Yes (?) Yes
target drive = protec Yes
Data validity check No
Drive parameters copied Yes
Vector calibration information copied Yes
Timer information copied No
1
Fault history copied No
1
Inverter based adjustments No
2
Application and system component adjustments Yes
3
OEM area created No (area not available)
Target module is exact copy of Master module Yes (except headers)
1 Data is not part of memory module contents but is retained in the inverter’s memory.
2 An example of an inverter based adjustment is resolver inverter electronics.
3 An example of an application and system component adjustment is resolver imprecision.