EasyManua.ls Logo

Lenze i550 Series - Page 114

Lenze i550 Series
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Inverter i550-C5.5/400-3 i550-C7.5/400-3 i550-C11/400-3 i550-C15/400-3
Rated power kW P
N
5.5 7.5 11 15
Rated power hp P
N
7.5 10 15 20
Mains voltage range 3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0-400/480 V
Rated mains current
without mains choke A I
r, AC
17.2 20 28.4 38.7
with mains choke A I
r, AC
12.4 15.7 22.3 28.8
Apparent output power kVA A
ON
8.7 11 16 22
Rated output current
2 kHz A I
OUT
13 16.5 23.5 32
4 kHz A I
OUT
13 16.5 23.5 32
8 kHz A I
OUT
13 16.5 23.5 32
16 kHz A I
OUT
8.7 11 15.7 21.3
Power loss
2 kHz W 137 172 242 340
4 kHz W 145 185 260 360
8 kHz W 190 240 340 460
16 kHz W 189 238 337 469
at inverter disablecontroller
inhibit
W 6 6 6 18
Overcurrent cycle 180 s
Max. output current A I
max, out
19.5 25 35 48
Overload me s t
ol
60 60 60 60
Recovery me s t
re
120 120 120 120
Max. output current during the
recovery me
A 9.8 12.4 17.6 24
Overcurrent cycle 15 s
Max. output current A I
max, out
26 33 47 64
Overload me s t
ol
3 3 3 3
Recovery me s t
re
12 12 12 12
Max. output current during the
recovery me
A 9.8 12.4 17.6 24
Cyclic mains switching 3 mes per minute
Brake chopper
Max. output current A I
max, 1
16.6 29 29 43
Min. brake resistance Ω R
min
47 27 27 18
Max. motor cable length shielded
without EMC category m 100 100 100 100
Category C1 (2 kHz, 4 kHz, 8
kHz)
m - - - -
Category C2 (2 kHz, 4 kHz, 8
kHz)
m 20 20 20 20
Category C3 (2 kHz, 4 kHz, 8
kHz)
m 35 50 50 35
Weight kg 2.3 3.7 3.7 10.3
Weight lb 5 8 8 23
Technical data
3-phase mains connecon 400 V
Rated data
114

Table of Contents

Other manuals for Lenze i550 Series

Related product manuals