Inverter i550-C18/400-3 i550-C22/400-3 i550-C30/400-3 i550-C37/400-3
Rated power kW P
N
18.5 22 30 37
Rated power hp P
N
25 30 40 50
Mains voltage range 3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0-400/480 V
Rated mains current
without mains choke A I
r, AC
48.4 - - -
with mains choke A I
r, AC
36 42 54.9 68
Apparent output power kVA A
ON
27 32 41 51
Rated output current
2 kHz A I
OUT
40 47 61 76
4 kHz A I
OUT
40 47 61 76
8 kHz A I
OUT
40 47 61 76
16 kHz A I
OUT
26.6 31.3 40.6 50.6
Power loss
2 kHz W 420 491 639 790
4 kHz W 450 520 680 840
8 kHz W 570 670 880 1100
16 kHz W 581 680 884 1095
at inverter disablecontroller
inhibit
W 18 18 25 25
Overcurrent cycle 180 s
Max. output current A I
max, out
60 71 92 114
Overload me s t
ol
60 60 60 60
Recovery me s t
re
120 120 120 120
Max. output current during the
recovery me
A 30 35 46 57
Overcurrent cycle 15 s
Max. output current A I
max, out
80 94 122 152
Overload me s t
ol
3 3 3 3
Recovery me s t
re
12 12 12 12
Max. output current during the
recovery me
A 30 35 46 57
Cyclic mains switching 3 mes per minute
Brake chopper
Max. output current A I
max, 1
52 52 98 98
Min. brake resistance Ω R
min
15 15 7.5 7.5
Max. motor cable length shielded
without EMC category m 100 100 100 100
Category C1 (2 kHz, 4 kHz, 8
kHz)
m - - - -
Category C2 (2 kHz, 4 kHz, 8
kHz)
m 20 20 20 20
Category C3 (2 kHz, 4 kHz, 8
kHz)
m 35 35 35 35
Weight kg 10.3 10.3 17.2 17.2
Weight lb 23 23 38 38
Technical data
3-phase mains connecon 400 V
Rated data