EasyManua.ls Logo

Lenze PROFIBUS E84AYCPM - Page 90

Lenze PROFIBUS E84AYCPM
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lenze · E84AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 5.0 EN · 11/2012 · TD17 90
11 Diagnostics
11.3 Advanced diagnostic message
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Example: "Short circuit (OC1)" error in the Inverter Drive 8400
Byte Value
[hex]
Description
1 x Standard data (PRM_Fault)
...
6
7 0A Block length of the advanced diagnostics = 10 bytes
8 81 Status message
900Slot 0
10 01 Status coming
11 00
12 00
13 0B Error message 0x11C4000B "Short circuit (OC1)"
Error type: "Warning locked"
Subject area: 0x11C4 (current)
Error ID: 0x000B
The error number "0x11C4000B" indicates the following:
In the "Current" subject area, an overcurrent has been detected. The error response
to this is a "Warning locked", which must be unlocked separately after the error has
been eliminated.
14 00
15 C4
16 11

Table of Contents

Related product manuals