2-16 Service Manual
5025-2xx, 4xx
122.15 Service
Fuser Error
Fuser storted thermistor check failed
for second thermistor
Go to “Fuser service check” on
page 2-32.
122.16 Service
Fuser Error
Estimated power is at or above
maximum power.
Go to “Fuser service check” on
page 2-32.
141.xx Service
Staging Motor
Staging motor error. Go to “Autocompensator mechanism
service check” on page 2-27.
141.01 Service
Staging Motor
Staging motor has exceeded the ramp
up table.
Go to “Autocompensator mechanism
service check” on page 2-27.
141.02 Service
Staging Motor
Staging motor has exceeded number
of encoders at minimum PWM.
Go to “Autocompensator mechanism
service check” on page 2-27.
141.03 Service
Staging Motor
Staging motor has exceeded number
of encoders at maximum PWM.
Go to “Autocompensator mechanism
service check” on page 2-27.
141.04 Service
Staging Motor
Motor encoder count did not change
between interrupts.
Go to “Autocompensator mechanism
service check” on page 2-27.
141.05 Service
Staging Motor
Staging motor has encountered a stall
timeout.
Go to “Autocompensator mechanism
service check” on page 2-27.
150.xx Service
Black/ITU cartridge
Motor
Black/ITU Cartridge Motor Go to “Main drive gear assembly (EP
drive) service check” on page 2-35.
150.01 Service
Black/ITU cartridge
Motor
Failed to achieve lock for motor within
allotted time.
Go to “Main drive gear assembly (EP
drive) service check” on page 2-35.
150.02 Service
Black/ITU cartridge
Motor
Timeout waiting for SAP BLDC motor
to reach valid FG speed.
Go to “Main drive gear assembly (EP
drive) service check” on page 2-35.
150.03 Service
Black/ITU cartridge
Motor
Timeout waiting for
MP_NUM_INITIAL_SAP_HALLS.
Go to “Main drive gear assembly (EP
drive) service check” on page 2-35.
150.04 Service
Black/ITU cartridge
Motor
Timeout waiting for SAP BLDC motor
FG.
Go to “Main drive gear assembly (EP
drive) service check” on page 2-35.
150.05 Service
Black/ITU cartridge
Motor
Lost lock for motor. Go to “Main drive gear assembly (EP
drive) service check” on page 2-35.
150.06 Service
Black/ITU cartridge
Motor
Excessive SAP BLDC PWM. Go to “Main drive gear assembly (EP
drive) service check” on page 2-35.
150.07 Service
Black/ITU cartridge
Motor
Motor stalled in time-based
commutation.
Go to “Main drive gear assembly (EP
drive) service check” on page 2-35.
152.xx Service
Cyan Cartridge Motor
Go to “Main drive gear assembly (EP
drive) service check” on page 2-35.
152.01 Service
Cyan Cartridge Motor
Failed to achieve lock for motor within
allotted time.
Go to “Main drive gear assembly (EP
drive) service check” on page 2-35.
152.02 Service
Cyan Cartridge Motor
Timeout waiting for SAP BLDC motor
to reach valid FG speed.
Go to “Main drive gear assembly (EP
drive) service check” on page 2-35.
Service error messages (1xx, 9xx) (continued)
Error code Description Action