Transfer Adjust
This setting controls the transfer roll algorithm.
To adjust this setting:
1 From the Diagnostics menu, navigate to:
EP Setup > Transfer Adjust
2 Press OK to save any changes.
Print Contrast
This setting controls the developer voltage
oset.
To adjust this setting:
1 From the Diagnostics menu, navigate to:
EP Setup > Print Contrast
2 Press OK to save any changes.
Charge Roll
This setting controls the charge roll voltage.
To adjust this setting:
1 From the Diagnostics menu, navigate to:
EP Setup > Charge Roll
2 Press OK to save any changes.
Gap Adjust
This setting adjusts the minimum gap between sheets. Increasing this value may reduce curl of some printed
media and eliminate some output bin stacking problems. However, increasing this value also results in slower
overall performance, measured in pages per minute.
The range of values is 0 to 255, and the default value is 0.
To adjust this setting:
1 From the Diagnostics menu, navigate to:
EP Setup > Gap Adjust
2 Press OK to save any changes.
Auto Dark Adj
When activated, this setting attempts to optimize the amount of toner used when printing with a specific
operating point.