Diagnostic information 2-95
4062
Go Back
Previous
Next
923.00 Fuser over
temperature failure.
Fuser type = 1
The fuser hot roll has
exceeded the proper operating
temperature.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to “Fuser unit
assembly removal on
page 4-22.
923.01 Fuser over
temperature failure.
Fuser type = 1
The fuser hot roll has
exceeded the proper operating
temperature.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to “Fuser unit
assembly removal on
page 4-22.
923.25 Fuser over
temperature failure.
Fuser type = 2
The fuser hot roll has
exceeded the proper operating
temperature.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to “Fuser unit
assembly removal on
page 4-22.
923.26 Fuser over
temperature failure.
Fuser type = 2
The fuser hot roll has
exceeded the proper operating
temperature.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to “Fuser unit
assembly removal on
page 4-22.
923.50 Fuser over
temperature failure.
Fuser type = 1
The fuser hot roll has
exceeded the proper operating
temperature.
Replace the fuser unit
assembly if problem remains.
Go to “Fuser unit assembly
removal” on page 4-22.
923.51 Fuser over
temperature failure.
Fuser type = 1
The fuser hot roll has
exceeded the proper operating
temperature.
Replace the fuser unit
assembly if problem remains.
Go to “Fuser unit assembly
removal” on page 4-22.