card reacts differently to temporary power failure depending on whether the leaf is open, closed or in an intermediate position:
Leaf closed: the operator reverts to normal operation.
Leaf open: after receiving two consecutive commands from the user the operator reverts to normal operation.
eaf in intermediate position: the automation remains immobile, when the fi rst command is given, it opens slowly, when the leaf is fully open, it reverts
When the power supply is switched back on, in a mode that envisages automatic closure, the operator waits a fi xed interval of 30 seconds and opens slowly.
When the leaf is fully open, the operator reverts to normal operation.
This function enables 4-second pre-fl ashing by the fl ashing light before starting the closure or opening motion.
This function enables the operation of the fl ashing light during the pause before starting the automatic closure cycle.
Do not use this function.