Form 403595 Page Number - 14
CHANGE FACTORY SETTINGS
Each meter is calibrated at the factory for use with motor oil (see Change Scale Factor, page 8).
The Unit of Measure is also selected prior to shipment.
Programming
To change the factory settings:
1. Press the
button to wake up the meter if
the display is blank.
2. To enter the Programming mode turn the unit
over. Press and hold down the
"PROGRAMMING" key located in the access
hole for 2 seconds (see picture on left).
3. After the display flashes, the Unit of
Measurement and Scale Factor are displayed.
4. The current Unit of Measurement will be flashing
when the programming mode has been entered.
Change Unit of Measure
The meter comes with an option to choose 4 different Units of Measure.
1. The actual Unit of Measure is flashing when the
Programming Mode is entered.
2. Press the
button to toggle between the four
options; PT, QT, GAL, L.
3. When the desired unit of measure is displayed,
press the button. The Unit of Measure icon
stops flashing.
4. If L, (Liters), is selected, the decimal point begins to flash.
You now have the option to change the decimal point to either a period or a comma.
To do this, press the button.
5. If no Scale Factor changes are necessary, go to Save Changes on page 8.
Use a 5/32” Allen
wrench or similar
blunt tool.
Location of access hole for PROGRAMMING Ke
y
Changing the Unit of Measurement from metric to English or from English to metric clears the
Re-settable Total and Accumulated Total.
Scale Factor Digits
Programming
Display
Unit of
Measurement
To order call 1-800-548-1191 or visit www.partdeal.com - info@partdeal.com

Other manuals for Lincoln B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lincoln B Series and is the answer not in the manual?

Lincoln B Series Specifications

General IconGeneral
BrandLincoln
ModelB Series
CategoryWater Pump
LanguageEnglish

Related product manuals