EasyManua.ls Logo

LinearX LT360 - Chapter 2: Command Reference; Goto CCW

LinearX LT360
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
LT360 Precision Turntable
DLL Programming Manual
Class Set (out)
Identifier lt_Goto_CCW
Hex Value 0x1C
Call LT360LIB_CmdValue(Handle, lt_Goto_CCW, '±nnn.n');
Parameter Position (degrees)
Description
This command causes the LT360 to move to the desired location specified
by the parameter value using counter clockwise rotation. If the LT360 is
already at this location, no movement occurs.
The parameter value should have tenths of a degree precision, and may be
either unipolar (0..+360.0) or bipolar (0..±180.0).
The Goto 0 command can also be issued from the front panel of the unit, or
the LR360 remote using the switches on the front panel.
2.1 Goto CCW

Other manuals for LinearX LT360