37
LT360 Precision Turntable
DLL Programming Manual
■ Class Set (out)
■ Identifier lt_SetMoveAbort
■ Hex Value 0x38
■ Call LT360LIB_CmdValue(Handle, lt_SetMoveAbort, null);
■ Parameter (none)
Description
This command can be used to terminate the rotation in progress. The LT360
will stop rotating as quickly as possible at any current location. This com-
mand can be used as an emergency stop feature if needed.
2.20 Set Move Abort