LT360 Precision Turntable
DLL Programming Manual
2.2 Goto CW
Class Set (out)
Identifier lt_Goto_CW
Hex Value 0x1D
Call LT360LIB_CmdValue(Handle, lt_Goto_CW, '±nnn.n');
Parameter Position (degrees)
Description
This command causes the LT360 to move to the desired location
specified by the parameter value using clockwise rotation. If the LT360
is already at this location, no movement occurs.
The parameter value should have tenths of a degree precision, and may
be either unipolar (0..+360.0) or bipolar (0..±180.0).
The Goto 0 command can also be issued from the front panel of the
unit, or the LR360 remote using the switches on the front panel.