4.3 Storage of Inverter
The following requirements should be met if the inverter will not be deployed immediately:
Do not unpack the inverter (put desiccant in the original box if the inverter is unpacked).
Store the inverter at a temperature range of -30° C to +70° C, and with the relative humidity
of 0% to 100% (no condensing).
In case of stacking storage, the number of stacking layers should never exceed the limit
marked on the outer side of the packing case.
The inverter should be stored in a clean and dry place and be protected from dust and water
vapor corrosion.
Do not store the inverter in places susceptible to direct sunlight, rain, and strong electric field.
Do not store the inverter in places with corrosive substances or susceptible to rodents and
insects.
Carry out periodic inspections. Inspection shall be conducted at least once every six months.
If any insect or rodent bites are found, replace the packaging materials in time.
If the inverter has been stored for more than a year, inspection and testing by professionals
are required before it can be put into operation.
If the inverter needs to be transported again, pack it strictly before transporting it.
NOTICE
Please store the inverter according to the storage requirements. Product damage caused
by failure to meet the storage requirements is not covered by the warranty.