5.1.2 Environment Requirements
The inverter must be installed in a ventilated environment to ensure good heat dissipation.
Make sure the installation meets the following conditions:
•
Not in areas where highly flammable materials are stored.
•
Not in potential explosive areas.
•
Not in the cool air directly.
•
Not near the television antenna or antenna cable.
•
Not higher than altitude of about 2000m above sea level.
•
Not in environment of precipitation or humidity (>95%).
•
The slope of the wall should be within ±5°.
•
The wall must be solid enough to bear the weight of the inverter.
•
Do not install the inverter on a wall made of gypsum boards or similar materials with weak
sound insulation to avoid noise disturbance in a residential area.
5.1.3 Angle and Space Requirements
•
Never install the inverter horizontally, or with a forward tilt or with a backward tilt or
even with upside down. The horizontal installation can result in damage to the inverter.
•
Install the inverter upright or at a maximum back tilt of 15 degrees to facilitate heat
dissipation.