• If choosing Li-Ion battery, make sure to connect the BMS communication cable between
the battery and the inverter.
• The CAN cable enables the communication between the inverter and the Li-Ion Battery.
• Communication interface between inverter and battery is CAN with a RJ45 connector.
• The battery communication can only work when the battery BMS is compatible with
the inverter.
Wiring Connection Procedure:
Step1: Assemble the BMS cable Connector
• Prepare a communication cable and insert the BMS cable connector which can be found in
the accessory box.
• Crimp the communication cable with an Rj45 plug which is inside of the BMS cable
connector.
Step2: Connect the BMS cable to the inverter
•
Insert the BMS cable connector into BMS port on the inverter and screw it tightly.
•
Then insert other side of communication cable into CAN port on the battery.
•
Make sure the Li-Ion battery BMS port connects to the inverter is Pin to Pin.