Air-bleeding from Fuel injection pump
1. Turn key switch to the “ON” position.
2. Loosen the air-bleed bolt by using a spanner and
turn it by hands until it stops.
3. If clean fuel without bubbles comes out, turn the
key switch to “OFF” position and tighten the air-
bleed bolt.
Tightening torque : 19.6~29.4 N.m
(14.54~21.81 lb-ft)
Cover the bleeding fuel with a rag so that it does not flow to other components.