EasyManua.ls Logo

Lucent Technologies CBX 500 - Interface Standards; Other Standards; Physical Interfaces; Physical Connectors

Lucent Technologies CBX 500
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IOP and IOA Module Specifications
32-port Channelized T1/E1 FR/IP IOM
Beta Draft Confidential
CBX 500 Multiservice WAN Switch Hardware Installation Guide 4/5/03A-7
Interface Standards
American National Standards Institute (ANSI) T1.231 (performance monitoring)
Other Standards
Frame Relay Forum FRF.5, FRF.8, and FRF.16
•ITU-TG.703
ITU-T G.704 basic frame structure and cyclic redundancy check (CRC)
implementations
ITU-T G.826 (performance parameters)
E1 Management Information Base (MIB) Request For Comment (RFC) 1406
(for near-end statistics)
RFC 1490 translation FRAD
HDLC/SDLC encapsulation FRAD (for X.25 traffic)
•CEMark
Physical Interfaces
32 physical ports per IOA module:
T1 mode: 24 DS0 channels per physical port (768 logical ports per IOM, each at
64 Kbps)
E1 mode: 30 TS0 channels per physical port (960 logical ports per IOM, each at
64 Kbps)
Physical Connectors
32-Port Channelized T1 FR/IP I/O connector panel: RJ48, 100-ohm
32-Port Channelized E1 FR/IP I/O connector panel: RJ48, 120-ohm