EasyManua.ls Logo

Lucent Technologies CBX 500 - Line Coding; Framing; Signal Levels; Table A-7. DS3 and DS1 Standards

Lucent Technologies CBX 500
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IOP and IOA Module Specifications
4-port Channelized DS3 Frame/IP IOP Module
Beta Draft Confidential
A-224/5/03 CBX 500 Multiservice WAN Switch Hardware Installation Guide
Line Coding
B3ZS
Framing
D4, ESF (CCITT)
Application Mode
C-bit parity, M13
Signal Levels
Receive: Peak pulse amplitude from 0.2 to 0.85 volts
Transmit: Conform to ANSI T1.102 pulse template and amplitude (0.36 volts to
0.85 volts) for cable up to 450 feet
Table A-7. DS3 and DS1 Standards
Level Standard
DS3 ANSI T1.103, ANSI T1.107/T1.107a, ANSI T1.231, ANSI
T1M1.3/91-003R3, GR-499-CORE, AT&T TR54016, RFC 1407
DS1 AT&T Publication 62411, GR-499-CORE, ANSI T1.403, ANSI
T1.107, RFC 1406