Observing Boot Messages
A-6 Communications Server Hardware Installation Guide
Use Table A-2 to interpret possible diagnostic boot messages.
Ta b l e A - 2 Interpreting the Diagnostic Boot Messages
Field Possible Message Explanation
Testing Low Memory ERROR This error indicates a boot failure. Record all
information to this point and contact Lucent
Remote Access Technical Support.
Testing System Clock ERROR This error indicates a boot failure. Record all
information to this point and contact Lucent
Remote Access Technical Support.
Testing System Memory ERROR at failed
memory address
This error indicates a boot failure. Record all
information to this point and contact Lucent
Remote Access Technical Support.
Checking Boot Rom ERROR This error indicates a boot failure. Record all
information to this point and contact Lucent
Remote Access Technical Support.
Calibrating 33MHz Processor speed.
Starting FLASH Boot N/A N/A
Booting from FLASH
type
AM29F040 Nonvolatile memory brand name.
Loading Image at 0fff0000 RAM address.
flash copy complete 17082 Counter for nonvolatile memory bytes
transferred to RAM. If the counter freezes,
record all information to this point and contact
Lucent Remote Access Technical Support.
Verifying Load Module
Checksum
Invalid Length for
Flash at RAM
address
This error indicates a boot failure. Record all
information to this point and contact Lucent
Remote Access Technical Support.
Starting Load Module N/A N/A