Appendix 2: Automatic Report Code List
System Event Default Contact ID Report Code
when using sections [790] to [795]
Default SIA Report Code
when using sections [790] to [795]
Arming with User Code (##) 3 4A1 - Close by user CL - Closing report
Auto arming 3 4A3 - Automatic close CA - Automatic closing
Late to close 3 452 - Late to close OT - Late to close
No movement 3 452 - Late to close NA - No activity
Partial arming 1 574 - Group bypass CG - Close area
Quick arming 3 408 - Quick arm CL - Closing report
Arm with PC software 3 4A7 - Remote arm/disarm CL - Closing report
Disarm with User Code (##) 1 4A1 - Open by user OP - Opening report
Disarm after alarm* with User Code (##) 1 4A1 - Open by user OP - Opening report
Cancel alarm** with User Code (##) 1 4A6 - Open by user OR - Disarm from alarm
Auto-arming cancellation 1 4A5 - Deferred open/close CE - Closing extend
Disarm with PC software 1 4A7 - Remote arm/disarm OP - Opening report
Disarm after an alarm with PC software 1 4A7 - Remote arm/disarm OR - Disarm from alarm
Cancel alarm with PC software 1 4A6 - Open by user OR - Disarm from alarm
Cancel paramedic alarm 1 4A6 - Open by user OR - Disarm from alarm
Zone bypassed (##) 1 57A - Zone bypass UB - Untyped zone bypass
Zone alarm (##) 1 13A - Burglary alarm BA - Burglary alarm
Fire alarm (##) 1 11A - Fire alarm FA - Fire alarm
Zone alarm restore (##) 3 13A - Burglary alarm restore BH - Burglary alarm restore
Fire alarm restore (##) 3 11A - Fire alarm restore FH - Fire alarm restore
Panic 1 - emergency 1 12A - Panic alarm PA - Panic alarm
Panic 2 - medical 1 1AA - Medical alarm MA - Medical alarm
Panic 3 - fire 1 115 - Pull station FA - Fire alarm
Recent closing 3 4AA - Open/Close CR - Recent closing
Global zone shutdown 1 574 - Group bypass CG - Close area
Duress alarm 1 121 - Duress HA - Hold-up alarm
Keypad lockout 1 421 - Access denied JA - User code tamper
Zone shutdown (##) 1 57A - Zone bypass UB - Untyped zone bypass
Zone tampered (##) 1 144 - Sensor tamper TA - Tamper alarm
Zone tamper restore (##) 3 144 - Sensor tamper restore TR - Tamper restoral
* An armed system is or was in alarm and was disarmed by a user.
** A disarmed system is or was in alarm (e.g. 24Hr. zone) and was disarmed by a user.
AC failure 1 3A1 - AC loss AT - AC trouble
Battery failure 1 3A9 - Battery test failure YT - System battery trouble
Auxiliary supply trouble 1 3AA - System trouble YP - Power supply trouble
Bell output current limit 1 321 - Bell 1 YA - Bell fault
Bell absent 1 321 - Bell 1 YA - Bell fault
Clock lost 1 626 - Time/date inaccurate JT - Time changed
Fire loop trouble 1 373 - Fire trouble FT - Fire trouble
RF interference 1 344 - RF receiver jam detection XQ - RF Interference
TLM trouble restore 3 351 - Telco 1 fault restore LR - Phone line restoral
AC failure restore 3 3A1 - AC loss restore AR - AC restoral
Battery failure restore 3 3A9 - Battery test restore YR - System battery restoral