40
BE57-646 ECLIPSE Guided Wave Radar Transmitter - FOUNDATION fieldbus
4.5 Model 706 Configuration Menu Device Setup
Home Screen
M
ain Menu
Device Setup Quick Start
I
d
entity
B
asic Config
I
/O Config
D
i
splay Config
Advanced Config
F
actory Config
M
easurement Type:
Level Only
Interface and Level
V
olume and Level
F
low
S
ystem Units
F
l
ow Units:
Cubic Ft/Second
C
ubic Ft/Minute
C
ubic Ft/Hour
Gallons/Minute
Gallons/Hour
M
il Gallons/Day
Liters/Second
Liters/Minute
Liters/Hour
C
ubic Meters/Hour
Level Units:
Inches
Feet
Millimeters
Centimeters
Meters
Head Units:
Inches
Feet
Millimeters
Centimeters
Meters
Flow Element:
Palmer-Bowlus Flume
Flume Channel Width:
4inches
6inches
8inches
10 inches
12 inches
15 inches
18 inches
21 inches
24 inches
27 inches
30 inches
Parshall Flume
Flume Channel Width:
1inch
2inches
3inches
6inches
9inches
12 inches
18 inches
24 inches
36 inches
48 inches
60 inches
72 inches
96 inches
120 inches
144 inches
V
n
otch Weir
V
-notch Weir Angle:
2
2.5°
30°
45°
60°
9
0
°
120°
R
ect Weir with Ends
0 to215.0feet
(0 to 65 m)
Rect Weir w/o Ends
0 to215.0feet
(0 to 65 m)
Cipolletti Weir
0 to215.0feet
(0 to 65 m)
Generic Equation
K
L
C
n
Custom Table
Custom Table Type:
Linear
Spline
CUSTOM TABLE
VALUES:
Up to 30 Pairs of
Head/Flow Data
Reference Distance:
11.8 inches to 100 feet
(30 cm to30m)
Maximum Head
(calculated, read only)
Maximum Flow
(calculated, read only)
Low Flow Cutoff:
0 to 9999999 cubic ft/min
T
O
TALIZER SETUP:
U
nits:
C
ubic Feet
Gallons
Mil Gallons
Liters
M
i
lLiters
Cubic Meters
NON-RESET
TOTALIZER:
Units:
Cubic Feet
Gallons
Mil Gallons
Liters
Mil Liters
Cubic Meters
Multiplier:
1
10
100
1,000
10,000
100,000
Value (read only)
RunTime (read only)
RESETTABLE
TOTALIZER:
Mode:
Disabled
Enabled
Units:
Cubic Feet
Gallons
Mil Gallons
Liters
Mil Liters
Cubic Meters
Multiplier:
1
10
100
1,000
10,000
100,000
Value (read only)
RunTime (read only)
Reset
L
evel Units:
I
nches
F
eet
Millimeters
C
e
ntimeters
Meters
Distance Units:
Inches
F
eet
M
illimeters
Centimeters
Meters
Temperature Units:
Celsius
Fahrenheit
P
robe Model:
7
Y
D Coax HTHP
7
Y
F Sngl Rod Std
7
YG Sngl Rod Std
7
YJ Sngl Rod HTHP Cages
7
YL Sngl Rod HP Cages
7YM Sngl Rod HPTanks
7YN Sngl Rod HTHP Tanks
7YP Coax HP
7YS Coax Steam
7
YT Coax Std
7Y1 Sngl Flex Std
7Y2 Sngl Flex Bulk
7Y3 Sngl Flex HP
7Y5 Twin Flex Bulk
7Y6 Sngl Flx HTHP Cage
7Y7 Twin Flex Clad
Probe Mount:
NPT
BSP
Flange
NPT/Flushing
BSP/Flushing
Flange/Flushing
Hygienic
Probe Coating:
None (Bare)
PFA Coated
Probe Length:
12 inches to100feet
(30 cm to30m)
Dielectric Range:
Below 1.7
1.7 to3.0
3.0 to10
Above 10
Flow Setup:

Table of Contents