21
7. Specifications
7.1. Specifications
Accuracy calculated as [%reading + (num. digits*resolution)] at 18 to 28°C; <75%HR.
Function
DC Voltage
Input impedance>10MΩ; Protection against overcharge: 1000VDC/AC RMS.
Range
Resolution
Accuracy
1000V
1V
600.0V
0.1V
60.00V
0.01V
±(1.5% + 5 digits)
6.000V
0.001V
600.0mV
0.1mV
±(0.5% + 8 digits)
AC TRMS Voltage
(50Hz-400Hz)
Input impedance>9MΩ; Protection against overcharge: 1000VDC/AC RMS.
Accuracy specified from 10% to 100% of the measuring range, sine wave.
Accuracy PEAK function: ±10%rdg, PEAK response time: 1ms.
VFD AC Voltage reading for reference only.
1000V
1V
600.0V
0.1V
60.00V
0.01V ±(1.5% + 5 digits)
6.000V
0.001V
Input impedance<300kΩ; Protection against overcharge: 1000VDC/AC RMS.
Accuracy specified from 10% to 100% of the measuring range, sine wave.
(50Hz-400Hz)
300.0V
0.1V
Voltage
60.00V
0.01V
±(3.0% + 40 digits)
LowZ AC TRMS
6.000V
0.001V
Input impedance>10MΩ; Protection against overcharge: 1000VDC/AC RMS.
1000V
1V
(50Hz-400Hz)
600.0V
0.1V
Voltage
60.00V
0.01V
±(2.5% + 20 digits)
AC+DC TRMS
6.000V
0.001V
DC Current
600.0A
0.1A
±(2.5% + 5 digits)
1000A
1A
±(2.8% + 5 digits)
Protection against overcharge: 1000ADC/AC RMS.
(50Hz-60Hz)
1000A
1A
±(2.8% + 5 digits)
AC TRMS Current
600.0A
0.1A
±(2.5% + 5 digits)
Protection against overcharge: 1000ADC/AC RMS.
(50Hz-400Hz)
3000A
1A
Flexible Coil
30.00A
0.01A
Current
300.0A
0.1A
±(3.0% + 5 digits)
Protection against overcharge: 3000ADC/AC RMS.
Accuracy specified from 10% to 100% of the measuring range, sine wave.