3-20
C EVERY 250 OPERATING HOURS
C1 DIFFERENTIAL OIL LEVEL
CHECK
For the 160 ATJ E3:
Set the lifting platform on a horizontal surface with the engine switched off.
- Remove the cap 1 (Fig. C1/1), the oil level should be flush with the hole.
- If necessary, top up the oil (See the LUBRICANTS section) via the filling hole 2 (Fig. C1/2).
- Refit and tighten the cap 1 (Fig. C1/1).
For the 160 ATJS E3:
Set the lifting platform on a horizontal surface with the engine switched off.
- Remove the cap 3 (Fig. C1/3), the oil level should be flush with the hole.
- If necessary, top up the oil (See the LUBRICANTS section) via this hole.
- Refit and tighten the cap 3 (Fig. C1/3) (tightening torque 6 daNm).
DIFFERENTIAL ON REAR AXLE
C1/2
C1/1
2
1
C1/3
3
647414 EN (27/05/2015)