Overload less than 25%
1 Sheaves Inspect all for damage.
2
Luffing
Mechanism/
Cylinder
Inspect for damage/leaks.
3
Collar-wear
pads
Inspect all for damage.
Overload from 25% to 49%
1 Sheaves Inspect all for damage.
2
Luffing
Mechanism/
Cylinder
Inspect for damage/leaks.
3
Collar-wear
pads
Inspect all for damage.
4 Collar-welds Inspect all for cracks.
5
Telescopic
Sections
Inspect for bent or twisted sections. Check the boom
for straightness.
6
Lift Cylinder
Head Area
Inspect for bends or cracked welds.
7
Turret-Base
Section
Inspect for cracked welds.
8
Locking Area
(Pin Booms)
Inspect for elongated holes.
9 Welds Inspect for cracks.
10 Paint
Inspect for cracked paint which could indicate twisted,
stretched, or compressed members.
Reference Only

Table of Contents

Other manuals for Manitowoc Grove RT540E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove RT540E and is the answer not in the manual?

Manitowoc Grove RT540E Specifications

General IconGeneral
BrandManitowoc
ModelGrove RT540E
CategoryConstruction Equipment
LanguageEnglish

Related product manuals