Part Number Preliminary 6/11 253
Four thermistors are located on the ice machine. They
are labeled T1, T2, T3, T4
T1 - Air or Water cooled Models
Liquid line temperature sensor located at the outlet
of the condenser.
T1 - Remote Condenser or Remote Condensing
Unit Models
Liquid line temperature sensor located at the inlet
of the receiver.
T2 - Air or Water cooled Models
Discharge line temperature sensor located near
the compressor.
T2 - Remote Condenser or Remote Condensing
Unit Models
Liquid line temperature sensor located at the outlet
of the receiver.
T3 -Single Expansion Valve Models
Suction line temperature sensor located at the inlet
of the evaporator.
T3 - Multiple Evaporator Models
Suction line temperature sensor located at the
outlet of evaporator #1.
T4 -Single Expansion Valve Models
Suction line temperature sensor located at the
outlet of the evaporator.
T4 - Multiple Evaporator Models
Suction line temperature sensor located at the
outlet of evaporator #2.

Table of Contents

Other manuals for Manitowoc Indigo Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Indigo Series and is the answer not in the manual?

Manitowoc Indigo Series Specifications

General IconGeneral
ModelIndigo Series
Ice TypeNugget
Cooling SystemAir-cooled, Water-cooled
Power SupplyVaries by model
MaterialStainless steel exterior
Water Connection1/2" NPT water inlet

Related product manuals