Part Number Preliminary 6/11 331
I1070C/ICVD1095
Remote Air-Cooled Condensing Unit Model
Characteristics vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24-HOUR ICE PRODUCTION
OPERATING PRESSURES
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10 70/21 90/32
-20 to 70/
-29 to 21
7.9-9.4 9.7-11.5 11.1-13.1
.75-2.5
80/27 8.4-10.0 10.2-12.1 11.6-13.7
90/32 8.9-10.6 10.8-12.8 12.3-14.6
100/38 9.5-11.3 11.4-13.5 13.1-15.5
110/43 9.9-11.8 12.0-14.2 13.9-16.4
1
Times in minutes.
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10 70/21 90/32
-20 to 70/
-29 to 21
950 800 710
80/27 900 760 680
90/32 860 725 645
100/38 810 690 610
110/43 780 660 580
1
Based on average ice slab weight of 6.2 - 7.2 lb.
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
psig
Suction
Pressure
psig
Discharge
Pressure
psig
Suction
Pressure
psig
-20 to 50/
-29 to 10
200-250 40-30 155-180 70-85
70/21 230-255 50-30 155-180 70-90
80/27 235-260 50-30 155-180 70-95
90/32 240-290 55-31 155-180 85-105
100/38 275-345 60-32 160-200 90-115
110/43 310-380 65-32 160-210 100-120