128 Part Number 80-1230-9 10/10
Discharge line temperature normal:
The ice machine continues to make ice.
Discharge line temperature below 155°F after
30 minutes of run time:
The ice machine will start another 60-minute Standby
Mode.
If the discharge line temperature drops below 155°F
for 3 continuous minutes during 7 consecutive cycles
the ice machine will start a SafeGuard Mode.
During the SafeGuard Mode the ”Disch Temp” light will
continually flash to indicate a Safeguard Mode. The
ice machine remains off until:
The toggle switch is moved from ICE to OFF, then
back to ICE.
Line voltage is interrupted and restored.
Indicator Light
Before 48 hours have elapsed:
After a Standby Mode has been initiated the Control
Board “Disch Temp“light will flash anytime the toggle
switch is placed in the OFF position.
After 48 hours have elapsed:
The SafeGuard will be automatically erased from memory
and the “Disch Temp” light will not flash.